Determine Location
We recommend a location near the center of the ceiling. If this isn’t possible, install at least 4 inches from the wall or the corner. For wall mounting, select a spot not more than 12 inches from the ceiling.
NOTE: New construction: Do not attach device head until after sanding, painting, and other dust creating situations are finished and cleaned up.
Wiring / General
1. Use ANSI/UL Listed wire for Class 1 requirements
2. Observe local code requirements, and use box connector to anchor cable to outlet box
3. Metal outlet boxes must be grounded to earth ground
Turn off electricity to prevent ELECTRICAL SHOCK and damage to device. Be sure the alternating current (AC) power to the device is not controlled by any on/off switch, or other type of switch, other than a fuse or circuit breaker. |
IMPORTANT: Ensure that all fluorescent lighting fixtures are properly grounded.
NOTE: The wiring to be used shall be in accordance with the provisions of article 300.3(B) 210 of the National Electrical Code (NFPA 70). Wire installation should be performed only by a licensed electrician.